Dewatering Pump

 

1. Semi-open, High Chrome Iron impeller with replaceable/adjustable High Chrome Iron Wear rings, increases wear Resistance, when pumpage contains abrasive particles. 1. Commercial, industrial dewatering and construction site drainage.
2. Double inside mechanical seals with silicon carbide faces, (both top and bottom) running in an oil filled chamber and further protected by a lip seal running against a replaceable, 420 stainless steel shaft sleeve, provides for the most durable seal design available. 2. Effluent transfer
3. Highly efficient, continuous duty air filled, copper wound motor with class B or F insulation, minimizes the cost of operation.

3. Decorative waterfalls and fountains

4. Built in thermal & amperage sensing, protector prevents motor failure due to overloading or accidental run - dry conditions. 4. Raw water supply from rivers or lakes
5. Double shielded, permanently lubricated, high temperature C3 ball bearings fated for a B-10 life of 60,000 hours, extend operational life.
6. Top discharge, flow-thru design enables operation at low water levels for extended periods.

 

Discharge Size 4", 8" Npt (100, 200mm)
Available in all Stainless Steel
Horsepower Range 20 - 150Hp. (1.5 - 11Kw)

Performance Range

Capacity 100 - 1700Gpm (.37 - 6.4 cubic metre/ min)
Head 30 - 600Ft. - 100 Ft. (1.5 - 30.4m)
Maximum water temperature 104F. (40C)

Materials of Construction

Casing Cast Iron
Impeller High Chrome Cast Iron
Shaft 420 Stainless Steel
Motor Frame Cast Iron, ASTM A48 Class 35
Fasteners 304 Stainless Steel

Mechanical Seal

Upper Seal

Silicon Carbide / Silicon Carbide (75 - 150 Hp.)

Silicon Carbide / Silicon Carbide (20-60 Hp.)

Lower Seal Silicon Carbide / Silicon Carbide
Elastomers NBR (Nitril Buna Rubber)
Impeller Type Semi-open, solids handling
Solids Handling Capability Strainer Opening Size

Motor Nomenclature

Type, Speed, Hz Air Filled, 3600 Rpm, 60 Hz.
Voltage, Phase 208/230/460/575 V.., 3 Phase
Insulation Class B (20 - 20 Hp.), Class F (40 - 150 Hp.)
Bearings Pre-lubricated, Double Shielded
Accessories Submersible Power Cable 49' up 100 Hp, 65' for 120 & 150 Hp. Length as Required
Operational Mode Manual TS-303 Float Switch

 

 

KTZ - LHW - KRS - KTV - GSZ